Home>Steel Tank>43 cfr � 31746 oil measurement by tank gauging

43 cfr � 31746 oil measurement by tank gauging

results for this questionFeedback43 CFR § 3174.6 Oil measurement by tank gauging

(a) The procedures for oil measurement by tank gauging must comply with the requirements outlined in this section.(b) The operator must follow the procedures identified in API 18.1 or API 18.2 (both incorporated by reference,see § 3174.3) as further specified in this paragraph to determine the quality and quantity of oil measured under field conditions at an FMP.(1) Isolate tank. results for this questionHow to measure the gravity of an API oil tank?How to measure the gravity of an API oil tank?(iii) Read and record the observed API oil gravity to the nearest 0.1 degree.Read and record the temperature reading to the nearest 1.0 °F.(5) Measure the opening tank fluid level.Take and record the opening gauge only after samples have been taken,unless automatic sampling methods are being used.43 CFR § 3174.6 - Oil measurement by tank gauging results for this questionWhat are the regulatory requirements for pressurized piping?What are the regulatory requirements for pressurized piping?Interstitial monitoring,vapor monitoring,groundwater monitoring,and statistical inventory reconciliation have the same regulatory requirements for piping as they do for tanks.See the Leak Detection Requirements Table for more information.What are the regulatory requirements for pressurized piping? A.An Automatic Line Leak Detector:Release Detection for Underground Storage Tanks (USTs

results for this questionWhat are the requirements for automatic tank gauging ( ATG )?What are the requirements for automatic tank gauging ( ATG )?(ii) For automatic tank gauging (ATG),comply with the requirements of API 3.1B,API 3.6,and API 18.2 (all incorporated by reference,see § 3174.3) and the following (A) The specific makes and models of ATG that are identified and described at blm.gov are approved for use;43 CFR § 3174.6 - Oil measurement by tank gauging § 3174.2 General requirements.,Subpart

Dec 30,2020·(d) An operator must obtain a BLM-approved FMP number under §§3173.12 and 3173.13 of this part for each oil measurement facility where the measurement affects the calculation of the volume or quality of production on which royalty is owed (i.e.,oil tank used for tank gauging,LACT system,CMS,or other approved metering device),except as 12345NextSubpart 3174Measurement of Oil,Part 3170 - ONSHORE OIL·Federal Oil and Gas Royalty Management Act of 1982 (FOGRMA) Regulations (43 CFR subpart 3162.7) Measurement on lease (unit,CA),unless approved Approval required for commingling Gas orifice meters,unless otherwise approved Oil tank gauge or PD meter,unless otherwise approved In the old days (1989-2016)

43 CFR § 3173.12 Applying for a facility measurement point

(2) Off-lease measurement or commingling and allocation of Federal or Indian production requires prior approval (see 43 CFR 3162.7-2,3162.7-3,3173.15,3173.16,3173.24,and 3173.25).(b) The BLM will not approve as an FMP a gas processing plant tailgate43 CFR § 3174.5 - Oil measurement by tank gauging Oil measurement by tank gauging must accurately compute the total net standard volume of oil withdrawn from a properly calibrated sales tank by following the activities prescribed in § 3174.6 and the requirements of § 3174.4 of this subpart to determine the quantity and quality of oil being removed.(b) Oil tank equipment.43 CFR § 3174.6 - Oil measurement by tank gauging (a) The procedures for oil measurement by tank gauging must comply with the requirements outlined in this section.(b) The operator must follow the procedures identified in API 18.1 or API 18.2 (both incorporated by reference,see § 3174.3 ) as further specified in this paragraph to determine the quality and quantity of oil measured under field conditions at an FMP .

43 CFR 3174.5 - Oil measurement by tank gauging - general

Oil measurement by tank gauging must accurately compute the total net standard volume of oil withdrawn from a properly calibrated sales tank by following the activities prescribed in § 3174.6 and the requirements of § 3174.4 of this subpart to determine the quantity and quality of oil being removed.(b) Oil tank equipment.(1) Each tank used for oil storage must comply with the recommended practices listed in API RP 12R1 (incorporated by reference,see § 3174.3).(2) Each oil storage tank 43 CFR 3174.6 - Oil measurement by tank gauging -(a) The procedures for oil measurement by tank gauging must comply with the requirements outlined in this section.(b) The operator must follow the procedures identified in API 18.1 or API 18.2 (both incorporated by reference,see § 3174.3) as further specified in this paragraph to determine the quality and quantity of oil measured under field conditions at an FMP.BUREAU OF LAND MANAGEMENTmethods authorized in 43 CFR 3162.7-2,i.e.,measurement by tank gauging,positive displacement metering,or other methods acceptable to the authorized officer.Proper oil measurement ensures that the Federal Government and Indian mineral owners receive the royalties due,as specified in the governing oil and gas leases.

Code of Federal Regulations - New Mexico Department

Code of Federal Regulations Title 43 - Public Lands Interior Volume 2 Date 2019-10-01 Original Date 2019-10-01 Title PART 3170 - ONSHORE OIL AND GAS PRODUCTION Oil measurement by tank gauginggeneral requirements.Oil measurement by tank gaugingprocedures.Coriolis Meter Overview43 CFR 3174 Overall concept Provide prescriptive measurement procedures as a default with the option for national approval of new or alternative equipment or methods that meet well-defined performance criteria.Oil Custody Transfer Approved (default methods) Manual tank gauging Automatic tank gaugingDEPARTMENT OF THE INTERIOR Bureau of Landand (3) Onshore Oil and Gas Operations; Federal and Indian Oil and Gas Leases; Measurement of Gas (81 FR 81516),codified at 43 CFR subpart 3175.Collectively,we refer to these three rules as the 2016 Final Rules. The 2016 Final Rules were prompted by external and internal oversight reviews,which found that many of the BLMs production measurement and accountability policies were

Federal Register : Onshore Oil and Gas Operations

A.General Overview of The Final RuleC.General Comments on The Proposed RulePublic OutreachAs discussed in the background section of this preamble,the BLM's rules concerning oil measurement found in Order 4 have not kept pace with industry standards and practices,statutory requirements,or applicable measurement technology and practices.The final rule enhances the BLM's overall production accountability efforts by addressing these concerns and ensuring that the oil produced from Federal and Indian (except Osage Tribe) leases is adequately accounted for,ultimately ensuring that all royalties duSee more on federalregister.govTankLogix Benefits Tank MonitoringMany county governments throughout the USA are starting to enforce the 43 CFR regulations on tank gauging devices.One of the main infractions of this order is the fact that many of the eternal gauging devices allow off gases to escape through an opening at the top of the tank. water and oil.If measurements are only off by 2 or 3 percent Fisher MR95 Series Pressure Regulator Emerson USAvailable Low Pressure Configurations.MR95L 2 to 30 psig / 0.14 to 2.1 bar outlet pressures.Available High Pressure Configurations.MR95H 5 to 150 psig / 0.35 to 10.3 bar outlet.MR95HP 15 to 400 psig / 1.0 to 27.6 bar outlet.MR95HT 15 to 300 psig / 1.0 to 20.7 bar outlet and up to 650°F / 343°C.How to Consistently Perform Manual Tank Gauging Gas Jun 15,2020·Specifically,43 CFR 3174.5 and 3174.6 outline the procedures for manual tank gauging.Measurement technicians need to understand the following elements to support accurate measurement of product on BLM designated land. 3174.5 outlines the general requirements for oil measurement by tank gauging.Understand the measurement objective of accurately computing the total NSV drawn from a tank.Understand how to use oil tank

Implementation of 43 CFR subparts 3174 and 3175 and Gas

Jun 29,2018·Background On November 17,2016,the BLM issued final rules for the measurement of oil and gas removed or sold from Federal and Indian leases (codified in 43 CFR Part 3170,subparts 3174 and 3175).Certain provisions in the new regulations require operators to use specific equipment or software approved by the BLM (upon recommendation of the PMT) and listed at blm.gov.MACK ENERGY CORPORATION Incidence of(opening gauge) and then measuring the height of the oil level in the tank after delivery (closing gauge).The opening and closing gauges are then used with the tank calibration charts (tank tables) to compute accurately the volume of oil withdrawn.Gauging may be accomplished by measuring the height of the oil level from the tank bottom or a fixed datum plate upward to the surface of the oil in the tankOil and Gas Site Security,Oil Measurement,and Gas On November 17,2016,the Bureau of Land Management (BLM) published in the Federal Register the three following final rules (1) Onshore Oil and Gas Operations; Federal and Indian Oil and Gas Leases; Site Security (81 FR 81365),codified at 43 CFR subparts 3170 and 3173; (2) Onshore Oil and Gas Operations; Federal and Indian Oil and Gas Leases; Measurement of Oil (81 FR 81462),codified at 43 CFR subpart 3174; and (3) Onshore Oil and Gas Operations; Federal and Indian Oil

People also askHow is oil measured by tank gauging procedures?How is oil measured by tank gauging procedures?§ 3174.6 Oil measurement by tank gauging - procedures.(a) The procedures for oil measurement by tank gauging must comply with the requirements outlined in this section.43 CFR § 3174.6 - Oil measurement by tank gauging Preliminary Field Studies on Worker Exposures to Volatile

Aug 21,2014·Two of 17 samples met or exceeded the ACGIH unadjusted value of 0.5 ppm value; six of 17 exceeded the adjusted value of 0.25 ppm.[vii] Task-based personal breathing zone samples for benzene collected during tank gauging on flowback tanks exceeded the NIOSH short-term exposure limit (STEL) for benzene (1 ppm as a 15-minute TWA).[ii] At several Release Detection for Underground Storage Tanks (USTs The features of manual tank gauging are Four measurements of the tank's contents must be taken weekly,two at the beginning and two at the end of at least a 36-hour period during which nothing is added to or removed from the tank (see Table of Test Standards for Manual Tank Gauging).

Some results are removed in response to a notice of local law requirement.For more information,please see here.Previous123456NextSubpart 3174Measurement of Oil,Part 3170 - ONSHORE

Dec 30,2020·§ 3174.6 Oil measurement by tank gaugingprocedures.§ 3174.7 LACT systemgeneral requirements.§ 3174.8 LACT systemcomponents and operating requirements.Update on Automatic Tank Gauging for Oil Lease TanksSpecifically,3174.5 and 3174.6 pertain to automatic tank gauging and allow the use of automatic tank gauging for custody transfer of product in an oil lease tank.3174.6 also allows for temperature measurement to be performed by the automatic tank gauging system and not manual measurement with glass thermometers as was legacy standard.Tank owners are no longer constrained by outdated regulations from being able to utilize an automatic tank gauging

Use SOPs to Increase Accuracy of Oil Storage Tank Custody

When thinking about manual tank gauging,the BLM cited a statistical analysis that manual tank gauging uncertainties range from 0.6 to 2.5 percent depending on the volume of oil removed from the tank at the point of sale.This can result in thousands of dollars in losses or discrepancies on a daily basis. Included in 43 CFR 3174

Main Steel Grades

The main products are carbon steel, wear plate, alloy steel, shipbuilding steel, hot/cold rolled steel, boiler steel, mild steel, seamless steel pipe, according to Americal standard ASTM, Japanese standard JIS, German standard DIN, EN, etc.

OUR FACTORY

Our mill has three steel plates production lines and Machining Platform

STEEL PLATE PRODUCTION LINE

STEEL PLATE PRODUCTION LINE

STEEL PIPE PRODUCTION LINE

STEEL PIPE PRODUCTION LINE

STEEL COIL PRODUCTION LINE

STEEL COIL PRODUCTION LINE

STEEL MACHINING CENTER

STEEL MACHINING CENTER

Contact Us

We are gradually formed four major advantageous products: steel plate, steel pipe, stainless steel, special steel, and established our own Machining processing center in order to meet customer's diverse requirements.

Welcome to contact us through online consulting, emails and hotline if you are interested in our company or products. Our staff will reply you within 24 hours.

  • E-mail: [email protected]
  • Tel: 0086-13569929107
  • Address: 50 Guohuai Road, Henan Province, China

Leave a Message